Back to CVE records
Critical 9.8Published Jun 7, 2023

CVE-2023-2186On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway…

Updated under an hour ago ()

Does this affect you?

It affects trianglemicroworks scada_data_gateway. Add what you run to find out whether that includes you.

No exploitation reported and no EPSS estimate yet.

On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.

CVSS
9.8 CRITICAL (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness (CWE)
CWE-134
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
Not loaded for this CVE
Assigned by
Not given
NVD analysis
Modified
Record last updated
Oct 23, 2026
First seen by InfoSec Signals
Oct 23, 2026

Affected products

Affected products
trianglemicroworks scada_data_gateway
trianglemicroworks:scada_data_gateway
through 5.01.03
NVD

References

  • third-party-advisory

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.