CVE-2025-71324Flowise - Arbitrary File Read via chatId Parameter
Updated under an hour ago ()
Does this affect you?
It affects Flowise and 1 other product. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
Flowise before 3.0.6 contains an arbitrary file read vulnerability in the chatId parameter of the /api/v1/get-upload-file and /api/v1/openai-assistants-file/download endpoints. The chatId value is not validated and is passed to streamStorageFile(), where a fallback file-lookup path constructed without the orgId is evaluated after the storage-directory containment check, allowing path traversal beyond the intended storage directory. Unauthenticated attackers can read sensitive files such as /root/.flowise/database.sqlite, exposing all database content in the default configuration.
- CVSS
- 7.5 HIGH (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Weakness (CWE)
- CWE-73
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- VulnCheck
- NVD analysis
- Modified
- Record last updated
- Jun 29, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.