Critical 9.8Published Jun 8, 2026

CVE-2026-11499Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow

Updated under an hour ago ()

Does this affect you?

It affects Tenda HG7 and 2 other products. Add what you run to find out whether that includes you.

No exploitation reported and no EPSS estimate yet.

A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.

CVSS
9.8 CRITICAL (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R
Weakness (CWE)
CWE-121, CWE-119
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
Not loaded for this CVE
Assigned by
VulDB
NVD analysis
Deferred
Record last updated
Oct 1, 2026
First seen by InfoSec Signals
Oct 9, 2026

Affected products

Affected products
Tenda HG7
tenda:hg7
300001138_en_xpon
CNA record
Tenda HG9
tenda:hg9
300001138_en_xpon
CNA record
Tenda HG10
tenda:hg10
300001138_en_xpon
CNA record

References

References

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.