CVE-2026-13584Information tampering and Denial-of-service (DoS) vulnerability in CC-Link IE TSN communication protocol
Updated under an hour ago ()
Does this affect you?
It affects Mitsubishi Electric Corporation MELSEC MX Controller MX-R model MXR300-16 and 59 other products. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, MELSEC iQ-L Series Motion Module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.
- CVSS
- 7.1 HIGH (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N
- Weakness (CWE)
- CWE-924
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- Mitsubishi
- NVD analysis
- Deferred
- Record last updated
- Sep 17, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.