Back to CVE records
Critical 9.3Published Jan 13, 2026

CVE-2026-22755Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi

Updated under an hour ago ()

Does this affect you?

It affects Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330. Add what you run to find out whether that includes you.

No exploitation reported and no EPSS estimate yet.

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.

CVSS
9.3 CRITICAL (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber
Weakness (CWE)
CWE-77
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
Not loaded for this CVE
Assigned by
larry_cashdollar
NVD analysis
Deferred
Record last updated
Jan 20, 2026
First seen by InfoSec Signals
Oct 9, 2026

Affected products

Affected products
Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330
vivotek:affected_device_model_numbers_are_fd8365_fd8365v2_fd9165_fd9171_fd9187_fd9189_fd9365_fd9371_fd9381_fd9387_fd9389_fd9391_fe9180_fe9181_fe9191_fe9381_fe9382_fe9391_fe9582_ib9365_ib93587lpr_ib9371_ib9381_ib9387_ib9389_ib939_ip9165_ip9171_ip9172_ip9181_ip9191_it9389_ma9321_ma9322_ms9321_ms9390_tb9330 (from the name)
0100a; 0106a; 0106b; 0107a; 0107b_1; 0109a; 0112a; 0113a; and 12 more ranges
CNA record

References

References

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.