CVE-2026-24428Tenda W30E V2 Incorrect Authorization Allows Administrator Password Change
Updated under an hour ago ()
Does this affect you?
It affects Shenzhen Tenda Technology Co., Ltd. W30E V2 and 1 other product. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain an authorization flaw in the user management API that allows a low-privileged authenticated user to change the administrator account password. By sending a crafted request directly to the backend endpoint, an attacker can bypass role-based restrictions enforced by the web interface and obtain full administrative privileges.
- CVSS
- 8.7 HIGH (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
- Weakness (CWE)
- CWE-863
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- VulnCheck
- NVD analysis
- Analyzed
- Record last updated
- May 13, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.