CVE-2026-31981HTML injection in Diagram tab and Graph view in Guardian/CMC before 26.2.0
Updated under an hour ago ()
Does this affect you?
It affects Nozomi Networks Guardian and 4 other products. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
A Stored HTML Injection vulnerability was discovered in the Diagram tab and Graph view due to a shared input validation function being insufficiently restrictive. An authenticated user with administrative privileges can inject malicious HTML tags into N2OS configuration data through multiple input vectors. When a victim views the affected data in the Diagram tab and Graph view, the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
- CVSS
- 5.9 MEDIUM (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L
- Weakness (CWE)
- CWE-79
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- Nozomi
- NVD analysis
- Modified
- Record last updated
- Aug 11, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.