CVE-2026-63354Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page.
Updated under an hour ago ()
Does this affect you?
It affects Siemens SIMATIC Drive Controller CPU 1504D TF and 59 other products. Add what you run to find out whether that includes you.
EPSS puts the chance of exploitation in the next 30 days at 0.45%, higher than 38% of scored CVEs.
Do this next
Free account, 1 product
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
- CVSS
- 9.6 CRITICAL (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
- Weakness (CWE)
- CWE-79
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- 0.45% (percentile 38)
- Assigned by
- siemens
- NVD analysis
- Awaiting Analysis
- Record last updated
- Oct 16, 2026