CVE-2026-63357Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page.
Updated under an hour ago ()
Does this affect you?
It affects Siemens SIMATIC Drive Controller CPU 1504D TF and 59 other products. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
- CVSS
- 6.1 MEDIUM (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
- Weakness (CWE)
- CWE-79
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- siemens
- NVD analysis
- Awaiting Analysis
- Record last updated
- Oct 14, 2026
- First seen by InfoSec Signals
- Oct 13, 2026
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.