CVE-2026-7865Hidden Console Command
Updated under an hour ago ()
Does this affect you?
It affects Crestron Electronics Touchpanels (x60/x70). Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
A hidden console command is vulnerable to command injection flaw when control characters are passed to its second argument. A third party researcher Eugene Lim had discovered vulnerability in the way console command passes to a popen function call. Attackers with authenticated access to SSH console of Crestron devices may use to run underlying OS commands.
- CVSS
- 7.4 HIGH (v4.0, CNA)CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
- Weakness (CWE)
- CWE-88
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- Crestron
- NVD analysis
- Awaiting Analysis
- Record last updated
- May 6, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
Affected products
Crestron Electronics Touchpanels (x60/x70) crestron_electronics:touchpanels_x60_x70 (from the name) | from 3.002.0043.001 through 3.003.0015.001; fixed at 3.003.0015.001 | CNA record |
References
- https://www.crestron.com/Software-Firmware/Firmware/Touchpanels/TS-770-TS-1070-TSS-770-TSS-1070-TSW-570/3-003-0015-001patch
- https://www.crestron.com/release_notes/tsw-xx70_3.003.0015.001_release_notes.pdfrelease-notes
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.