CVE records

Every CVE as the CVE Program publishes it, refreshed every ten minutes, with NVD's analysis, CISA's known-exploited status and a healthcare tag. Free accounts get a daily email of the CVEs that match up to 3 of their products on My program; subscribers get each one the moment it is published. Where the data comes from: sources.

Updated under an hour ago ()

What this means for you

This week: 3,354 CVEs published, 232 critical, and 2 newly confirmed exploited. Add your stack to see whether any of them hit you.

Published in the last 7 days
3,354
Show in the list
Critical, last 7 days
232
Show in the list
Healthcare-tagged, last 7 days
5
Show in the list
Known exploited (CISA KEV)
1,764
Show in the list

Showing CVEs that name the product baxter:sigma_spectrum_infusion_system_firmware. Show all products

Free: a daily email for up to 3 products and the weekly digest. No card, no password. By continuing you agree to the Terms and Privacy Policy.

10 CVEs
Showing 1 to 10.
CVESeverityTitlePublished
CVE-2014-5434
Healthcare
Critical 9.8Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol.
Assigned by icscert
Mar 26, 2019
CVE-2014-5433
Healthcare
Critical 9.8An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700…
Assigned by icscert
Mar 26, 2019
CVE-2014-5432
Healthcare
Critical 9.8Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication.
Assigned by icscert
Mar 26, 2019
CVE-2014-5431
Healthcare
Medium 6.8Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information…
Assigned by icscert
Mar 26, 2019
CVE-2020-12047
Healthcare
Critical 9.8The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard…
Assigned by icscert
Jun 29, 2020
CVE-2020-12043
Healthcare
Critical 9.8The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted.
Assigned by icscert
Jun 29, 2020
CVE-2020-12045
Healthcare
Critical 9.8The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded creden…
Assigned by icscert
Jun 29, 2020
CVE-2020-12041
Healthcare
Critical 9.4The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to netw…
Assigned by icscert
Jun 29, 2020
CVE-2020-12039
Healthcare
Low 2.4Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered…
Assigned by icscert
Jun 29, 2020
CVE-2020-12040
Healthcare
Critical 9.8Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication c…
Assigned by icscert
Jun 29, 2020

CVSS is the assigning CNA's score where it gives one, otherwise NVD's. The healthcare tag is a documented heuristic (a list of clinical and health IT vendors, and clinical terms in the description), not a classification. The CVE record is authoritative.